Formula

E = 10^(-1/slope)

Inputs

InputUnitDefault
Standard curve slope—-3.32
R squared—0.99

Worked example

With the default inputs: Efficiency = 100.1 %, Amplification factor per cycle = 2.001.

  1. E = 10^(-1/slope) = 10^(-1/-3.32) = 2.000805; efficiency = (E-1) x 100 = 100.0805%

Assumptions and limits

Check units before trusting a result. Warnings under the result flag out-of-range inputs and violated assumptions. For regulated work, confirm the result in your validated system.

More tools: qPCR analysis

Frequently asked questions

How does the qPCR efficiency from standard curve work?

It applies the formula E = 10^(-1/slope) in your browser and shows every step, so you can check it by hand.

Is my data uploaded?

No. The calculation runs entirely in your browser. A share link only puts your inputs in the page address.

Do this analysis in BioStudioAI

Upload the raw file and BioStudioAI fits, quality-checks and reports it with an audit trail.

See the platform →

Related

Absolute vs relative qPCR quantification

Relative quantification (delta delta Ct) answers 'how many times more than control'; absolute quantification answers 'how many copies', using a calibr

Digital PCR versus qPCR: when partitions win

Digital PCR counts molecules by partitions, giving absolute numbers tolerant of efficiency differences and inhibitors. qPCR wins on throughput, cost a

How to calculate fold change (qPCR and beyond)

Fold change is the ratio of a normalized measurement in a sample to the same measurement in a control. In qPCR it usually comes from 2 to the power of

qPCR