Tools & calculators · BioStudioAI
Pfaffl efficiency-corrected ratio
Efficiency-corrected relative expression (Pfaffl method). Results update as you type and the working is shown underneath. Nothing is uploaded.
Formula
ratio = E_target^dCt / E_ref^dCt
Inputs
| Input | Unit | Default |
|---|---|---|
| Target efficiency (factor) | — | 1.95 |
| Reference efficiency (factor) | — | 1.98 |
| Delta Ct target (control-sample) | — | 2 |
| Delta Ct reference (control-sample) | — | 0.2 |
Worked example
With the default inputs: Expression ratio = 3.317 x.
- ratio = 1.95^2 / 1.98^0.2 = 3.316929
Assumptions and limits
Check units before trusting a result. Warnings under the result flag out-of-range inputs and violated assumptions. For regulated work, confirm the result in your validated system.
More tools: qPCR analysis
Frequently asked questions
How does the Pfaffl efficiency-corrected ratio work?
It applies the formula ratio = E_target^dCt / E_ref^dCt in your browser and shows every step, so you can check it by hand.
Is my data uploaded?
No. The calculation runs entirely in your browser. A share link only puts your inputs in the page address.
Upload the raw file and BioStudioAI fits, quality-checks and reports it with an audit trail.
See the platform →Related
Relative quantification (delta delta Ct) answers 'how many times more than control'; absolute quantification answers 'how many copies', using a calibr
Digital PCR counts molecules by partitions, giving absolute numbers tolerant of efficiency differences and inhibitors. qPCR wins on throughput, cost a
Fold change is the ratio of a normalized measurement in a sample to the same measurement in a control. In qPCR it usually comes from 2 to the power of