Protocols · BioStudioAI
DNA ligation protocol
T4 DNA ligase joins compatible ends; molar ratio, insert quality and controls decide colony quality more than ligase brand.
Principle
T4 DNA ligase joins compatible ends; molar ratio, insert quality and controls decide colony quality more than ligase brand. This page gives a vendor-neutral bench workflow. Follow your kit insert for kit-specific volumes, and validate the assay in your own matrix before using it for decisions.
Materials and equipment
| Item | Notes |
|---|---|
| Samples and standards | Same matrix where possible; standards on every plate/run |
| Core reagents | Generic names; record supplier, catalogue and lot in the run record |
| Equipment | Calibrated pipettes, appropriate reader/instrument, timers |
| Consumables | Low-bind tubes/plates as the assay requires |
Solutions to prepare
Prepare buffers fresh or verify stored buffers. Use the buffer recipe, dilution and molarity calculators in Tools to scale recipes, and record what you actually made.
Procedure
- Dephosphorylate vector where background is a problem; gel-purify insert and vector.
- Calculate insert mass with the ligation calculator (commonly 3:1 insert:vector).
- Set up ligase reactions plus vector-only and no-ligase controls.
- Incubate (commonly 1 h room temperature or overnight 16°C).
- Transform and compare colony counts against controls.
Bench mode
Work through the procedure top to bottom, ticking steps off on paper or a phone. Keep total time in mind: this protocol takes about 1 h to overnight.
Expected results and QC
Vector-only colonies much lower (often under 10-20%) than the ligation. If a criterion fails, troubleshoot before analyzing samples: see Troubleshooting, and repeat rather than rescue.
Data analysis
Analyze with the matching calculator or guide in Tools and Guides, keep the raw file, and record the analysis settings with the result.
Troubleshooting
Common failures and fixes are in the Troubleshooting section for this assay family. Start with the control pattern: it usually names the failing step.
Safety and waste
Standard molecular-biology PPE. Research use only. This protocol is not medical or clinical advice.
FAQ
| Question | Answer |
|---|---|
| How long does it take? | About 1 h to overnight, excluding preparation and analysis. |
| What is the most common failure? | Skipped or failed controls, followed by samples read outside the validated range. |
| Can I scale it? | Yes: scale reagents with the Tools calculators and keep ratios and timing unchanged. |
References
Frequently asked questions
How long does it take?
About 1 h to overnight.
References
- Assay Guidance Manual · NCBI Bookshelf / Eli Lilly & NCATS (2024)
- MIQE Guidelines (Bustin et al.) · Clinical Chemistry (2009)
- Cold Spring Harbor Protocols · Cold Spring Harbor Laboratory Press (2024)
Upload the raw file and BioStudioAI fits, quality-checks and reports it with an audit trail.
See the platform →Related
Reporters (fluorescent proteins, luciferase) measure what their promoter, maturation and detection allow. Include promoter-less and constitutive contr
Screen cheap-to-expensive: colony PCR for presence/size, diagnostic digest for structure, sequencing for truth at every junction. Each stage discards
Choose restriction cloning for simple single inserts with good sites, Gibson/isothermal assembly for scar-light multi-fragment builds, and Golden Gate