Journal Watch · Neuron · 2026

Two-photon voltage imaging with rhodopsin-based sensors.

Utilizing Jarvis and pAce, we establish high-SNR action potential detection at kilohertz imaging rates in mouse hippocampal slices, zebrafish larvae, and the cortex of awake mice, demonstrating high-contrast action potential detection under 2P illumination with rhodopsin-based GEVIs in vitro and in vivo.

Grimm C, Sims RR, Tanese D et al.Neuron3 min readPharma relevance 30/100

DOI: 10.1016/j.neuron.2025.12.014PMID: 41687614Study type: preclinical (animal / model) study

TL;DR

Utilizing Jarvis and pAce, we establish high-SNR action potential detection at kilohertz imaging rates in mouse hippocampal slices, zebrafish larvae, and the cortex of awake mice, demonstrating high-contrast action potential detection under 2P illumination with rhodopsin-based GEVIs in vitro and in vivo.

Key findings

  • We further show 2P usability of the fluorescence resonance energy transfer (FRET)-opsin GEVIs pAce and Voltron2.
  • Comparing 2P scanless with fast 2P scanning illumination revealed that responses are resolved with both approaches, but FRET-opsin GEVIs show improved signal-to-noise ratio (SNR) with low irradiance, inherent to scanless illumination.
  • Utilizing Jarvis and pAce, we establish high-SNR action potential detection at kilohertz imaging rates in mouse hippocampal slices, zebrafish larvae, and the cortex of awake mice, demonstrating high-contrast action potential detection under 2P illumination with rhodopsin-based GEVIs in vitro and in vivo.

What they did

Here, we demonstrate compatibility of rhodopsin-based GEVIs with 2P illumination. We rationally engineer a fully genetically encoded, rhodopsin-based GEVI, just another voltage indicating sensor (Jarvis), and demonstrate its utility under 1P and 2P illumination.

Full abstract (original)

Background: Advances in optical techniques and two-photon (2P) sensitive genetic voltage indicators (GEVIs) enabled in-depth voltage imaging at single-spike and single-cell resolution. These results were achieved using ASAP-type sensors, while rhodopsin-based GEVIs were mainly used with one-photon (1P) illumination.

What they did: Here, we demonstrate compatibility of rhodopsin-based GEVIs with 2P illumination. We rationally engineer a fully genetically encoded, rhodopsin-based GEVI, just another voltage indicating sensor (Jarvis), and demonstrate its utility under 1P and 2P illumination.

Results & conclusions: We further show 2P usability of the fluorescence resonance energy transfer (FRET)-opsin GEVIs pAce and Voltron2. Comparing 2P scanless with fast 2P scanning illumination revealed that responses are resolved with both approaches, but FRET-opsin GEVIs show improved signal-to-noise ratio (SNR) with low irradiance, inherent to scanless illumination. Utilizing Jarvis and pAce, we establish high-SNR action potential detection at kilohertz imaging rates in mouse hippocampal slices, zebrafish larvae, and the cortex of awake mice, demonstrating high-contrast action potential detection under 2P illumination with rhodopsin-based GEVIs in vitro and in vivo.

Abstract © the authors / Neuron (2026). Reproduced here for discussion and indexing, with attribution. Read the original at https://doi.org/10.1016/j.neuron.2025.12.014 · PubMed 41687614.

Why it matters for pharma & biotech

  • Relevant to Biology & Life Sciences teams tracking Neuron for new targets, mechanisms and biomarkers.
  • As earlier-stage work, its near-term value is target validation and assay design rather than clinical decisions.
  • For searchers: the full abstract is reproduced below, so you can judge relevance before opening the publisher page.

Limitations & what to check in the full text

  • This brief is based on the published abstract only. Effect sizes, subgroup results and safety detail in the full text may qualify the headline findings.
  • The work is preclinical. Results in animal or cell models frequently do not translate directly to human efficacy or safety.
  • The abstract reports its conclusions qualitatively, without headline effect sizes — read the full text before citing a magnitude.

Frequently asked questions

What did this Neuron study find?

Utilizing Jarvis and pAce, we establish high-SNR action potential detection at kilohertz imaging rates in mouse hippocampal slices, zebrafish larvae, and the cortex of awake mice, demonstrating high-contrast action potential detection under 2P illumination with rhodopsin-based GEVIs in vitro and in vivo.

What type of study is this?

It is a preclinical (animal / model) study, published in Neuron in 2026. Here, we demonstrate compatibility of rhodopsin-based GEVIs with 2P illumination.

Where can I read the original paper?

The original is at the publisher via DOI 10.1016/j.neuron.2025.12.014. PubMed ID: 41687614. BioStudioAI reproduces the abstract for discussion and links to the source.

How to cite the original: Grimm C, Sims RR, Tanese D et al.. Two-photon voltage imaging with rhodopsin-based sensors.. Neuron (2026). DOI: 10.1016/j.neuron.2025.12.014.
This brief: BioStudioAI Journal Watch, 29 October 2026. https://biostudioai.com/blog/papers/two-photon-voltage-imaging-with-rhodopsin-based-sensors-512014/

Reading papers is step one. Analysing the data is the work.

BioStudioAI turns raw lab files into QC'd results, statistics, figures, reports and slides — hosted on your servers, every number computed, nothing typed.

Open BioStudioAI More guides