Journal Watch · Circulation · 2026

Risk-Guided Screening for Atrial Fibrillation Using Electronic Health Records.

In the FinACAF registry, the rate of ischemic stroke for patients with high FIND-AF 2.0 risk, AF, and no anticoagulants was 6.0 events per 100 patient-years.<h4>Conclusions</h4>The EHR-based machine learning model, FIND-AF 2.0, identifies a high-risk subpopulation for AF diagnosis among patients at elevated risk of stroke and could enable scalable, EHR-driven, risk-guided AF screening.

Nadarajah R, Wu J, Wahab A et al.Circulation4 min readPharma relevance 75/100

DOI: 10.1161/circulationaha.126.079391PMID: 42517218Study type: cohort / observational clinical study

TL;DR

In the FinACAF registry, the rate of ischemic stroke for patients with high FIND-AF 2.0 risk, AF, and no anticoagulants was 6.0 events per 100 patient-years.<h4>Conclusions</h4>The EHR-based machine learning model, FIND-AF 2.0, identifies a high-risk subpopulation for AF diagnosis among patients at elevated risk of stroke and could enable scalable, EHR-driven, risk-guided AF screening.

Key findings

  • Of 1923 participants from 15 sites in the prospective study (mean age, 70.2 [SD 9.4] years), with a mean of 74.8 (SD, 19.4) ECG recordings, AF was diagnosed in 5 of 902 (0.6%) with low FIND-AF 2.0 risk and 46 of 1021 (4.5%) with high FIND-AF 2.0 risk (odds ratio, 8.46 [95% CI, 3.35-21.40], <i>P</i><0.001).
  • Median AF burden among high FIND-AF 2.0 risk-detected cases was 33.4% (interquartile range, 5.1%-91.6%), and 96.1% initiated oral anticoagulants.
  • In the FinACAF registry, the rate of ischemic stroke for patients with high FIND-AF 2.0 risk, AF, and no anticoagulants was 6.0 events per 100 patient-years.<h4>Conclusions</h4>The EHR-based machine learning model, FIND-AF 2.0, identifies a high-risk subpopulation for AF diagnosis among patients at elevated risk of stroke and could enable scalable, EHR-driven, risk-guided AF screening.

Numbers at a glance (from the abstract)

n=2n=7n=627n=149n=22995%0.6%4.5%33.4%5.1%91.6%96.1%

Every figure above is taken verbatim from the abstract below. Check the full text for denominators, confidence intervals and subgroup detail.

What they did

We conducted a prospective study where participants ≥30 years old without AF and with a CHA<sub>2</sub>DS<sub>2</sub>-VASc score ≥2 in men and ≥3 in women, stratified by FIND-AF 2.0 into high and low risk, undertook 4 ECG recordings per day for 3 weeks using a handheld ECG recorder, with a primary outcome of newly diagnosed AF. We estimated stroke risk associated with nonanticoagulated AF in patients with high FIND-AF 2.0 risk in the FinACAF (Finnish Anticoagulation in Atrial Fibrillation) registry of patients with AF (n=229 565).<h4>Results</h4>FIND-AF 2.0 was applicable to all EHRs and showed good to excellent prediction performance (United Kingdom: area under the receiver operating characteristic curve [AUROC], 0.819 [95% CI, 0.809-0.829]; Israel: AUROC, 0.835 [95% CI, 0.828-0.842]; Japan: AUROC, 0.751 [95% CI, 0.745-0.757]; Canada: AUROC, 0.747 [95% CI, 0.741-0.753]; China: AUROC, 0.753 [95% CI, 0.725-0.771]), with AUROC>0.7 in men and women in all cohorts, and improved performance compared with CHA<sub>2</sub>DS<sub>2</sub>-VASc and C<sub>2</sub>HEST (coronary artery disease or chronic obstructive pulmonary disease [1 point each]; hypertension [1 point]; elderly [age ≥75 years, 2 points]; systolic HF [2 points]; thyroid disease [hyperthyroidism, 1 point]).

Full abstract (original)

Background: <h4>Background</h4>Screening for atrial fibrillation (AF) on the basis of AF risk may be more effective. We aimed to develop, externally validate, and prospectively test a machine learning prediction model using electronic health records (EHRs) to guide AF screening.<h4>Methods</h4>We developed and validated a random forest prediction model for new AF within 6 months, using age, sex, and 10 comorbidities (Future Innovations in Novel Detection of Atrial Fibrillation [FIND-AF] 2.0) in EHRs in the United Kingdom (n=2 081 139), Japan (n=7 795 244), Israel (n=2 166 795), Canada (n=627 919), and China (n=149 145).

What they did: We conducted a prospective study where participants ≥30 years old without AF and with a CHA<sub>2</sub>DS<sub>2</sub>-VASc score ≥2 in men and ≥3 in women, stratified by FIND-AF 2.0 into high and low risk, undertook 4 ECG recordings per day for 3 weeks using a handheld ECG recorder, with a primary outcome of newly diagnosed AF. We estimated stroke risk associated with nonanticoagulated AF in patients with high FIND-AF 2.0 risk in the FinACAF (Finnish Anticoagulation in Atrial Fibrillation) registry of patients with AF (n=229 565).<h4>Results</h4>FIND-AF 2.0 was applicable to all EHRs and showed good to excellent prediction performance (United Kingdom: area under the receiver operating characteristic curve [AUROC], 0.819 [95% CI, 0.809-0.829]; Israel: AUROC, 0.835 [95% CI, 0.828-0.842]; Japan: AUROC, 0.751 [95% CI, 0.745-0.757]; Canada: AUROC, 0.747 [95% CI, 0.741-0.753]; China: AUROC, 0.753 [95% CI, 0.725-0.771]), with AUROC>0.7 in men and women in all cohorts, and improved performance compared with CHA<sub>2</sub>DS<sub>2</sub>-VASc and C<sub>2</sub>HEST (coronary artery disease or chronic obstructive pulmonary disease [1 point each]; hypertension [1 point]; elderly [age ≥75 years, 2 points]; systolic HF [2 points]; thyroid disease [hyperthyroidism, 1 point]).

Results & conclusions: Of 1923 participants from 15 sites in the prospective study (mean age, 70.2 [SD 9.4] years), with a mean of 74.8 (SD, 19.4) ECG recordings, AF was diagnosed in 5 of 902 (0.6%) with low FIND-AF 2.0 risk and 46 of 1021 (4.5%) with high FIND-AF 2.0 risk (odds ratio, 8.46 [95% CI, 3.35-21.40], <i>P</i><0.001). Median AF burden among high FIND-AF 2.0 risk-detected cases was 33.4% (interquartile range, 5.1%-91.6%), and 96.1% initiated oral anticoagulants. In the FinACAF registry, the rate of ischemic stroke for patients with high FIND-AF 2.0 risk, AF, and no anticoagulants was 6.0 events per 100 patient-years.<h4>Conclusions</h4>The EHR-based machine learning model, FIND-AF 2.0, identifies a high-risk subpopulation for AF diagnosis among patients at elevated risk of stroke and could enable scalable, EHR-driven, risk-guided AF screening.

Abstract © the authors / Circulation (2026). Reproduced here for discussion and indexing, with attribution. Read the original at https://doi.org/10.1161/circulationaha.126.079391 · PubMed 42517218.

Why it matters for pharma & biotech

  • Directly relevant to teams in AI in drug discovery / diagnostics — the abstract reports new data in that space, so competitive and pipeline teams should read the full text.
  • Because it reports human data, it can inform indication, endpoint and comparator decisions faster than preclinical work.
  • For searchers: the full abstract is reproduced below, so you can judge relevance before opening the publisher page.

Modalities & themes detected: AI in drug discovery / diagnostics

Limitations & what to check in the full text

  • This brief is based on the published abstract only. Effect sizes, subgroup results and safety detail in the full text may qualify the headline findings.

Frequently asked questions

What did this Circulation study find?

In the FinACAF registry, the rate of ischemic stroke for patients with high FIND-AF 2.0 risk, AF, and no anticoagulants was 6.0 events per 100 patient-years.<h4>Conclusions</h4>The EHR-based machine learning model, FIND-AF 2.0, identifies a high-risk subpopulation for AF diagnosis among patients at elevated risk of stroke and could enable scalable, EHR-driven, risk-guided AF screening.

What type of study is this?

It is a cohort / observational clinical study, published in Circulation in 2026. We conducted a prospective study where participants ≥30 years old without AF and with a CHA<sub>2</sub>DS<sub>2</sub>-VASc score ≥2 in men and ≥3 in women, stratified by FIND-AF 2.0 into high and low risk, undertook 4 ECG recordings per day for 3 weeks using a handheld ECG recorder, with a primary outcome of newly diagnosed AF.

Where can I read the original paper?

The original is at the publisher via DOI 10.1161/circulationaha.126.079391. PubMed ID: 42517218. BioStudioAI reproduces the abstract for discussion and links to the source.

How to cite the original: Nadarajah R, Wu J, Wahab A et al.. Risk-Guided Screening for Atrial Fibrillation Using Electronic Health Records.. Circulation (2026). DOI: 10.1161/circulationaha.126.079391.
This brief: BioStudioAI Journal Watch, 29 October 2026. https://biostudioai.com/blog/papers/risk-guided-screening-for-atrial-fibrillation-using-electronic-health-re-079391/

Reading papers is step one. Analysing the data is the work.

BioStudioAI turns raw lab files into QC'd results, statistics, figures, reports and slides — hosted on your servers, every number computed, nothing typed.