Journal Watch · Diabetes Care · 2026

High-Amplitude and Prolonged Glucose Excursions as a Key Determinant of Discordance Between Glucose Management Indicator and Glycated Hemoglobin in Type 1 Diabetes.

GRID-derived excursion metrics modify the relationship between GMI/uGMI and glycemia-associated risk.

Park S, Cho SH, Kim S et al.Diabetes Care3 min readPharma relevance 40/100

DOI: 10.2337/dc25-2820PMID: 42081254Study type: research study

TL;DR

GRID-derived excursion metrics modify the relationship between GMI/uGMI and glycemia-associated risk.

Key findings

  • In restricted cubic spline analyses, adjustment for GRID-derived excursion metrics differentially reshaped the associations of HbA1c, GMI, and uGMI with albuminuria and elevated triglyceride-glucose index in an outcome- and context-dependent manner, preferentially enhancing the informativeness of GMI and uGMI but not HbA1c.<h4>Conclusions</h4>Frequent high and prolonged glucose excursions were consistently associated with GMI-HbA1c discordance across devices, HbA1c strata, and analytic conditions.
  • GRID-derived excursion metrics modify the relationship between GMI/uGMI and glycemia-associated risk.

Numbers at a glance (from the abstract)

95%P < 0.001

Every figure above is taken verbatim from the abstract below. Check the full text for denominators, confidence intervals and subgroup detail.

What they did

Glucose excursions were quantified using the glucose rate increase detector (GRID) algorithm with varied peak glucose and time-to-peak thresholds. Discordance was defined using GMI-to-HbA1c and updated GMI (uGMI)-to-HbA1c ratios, and associations with GRID-derived excursion metrics were evaluated alongside conventional CGM-derived variability metrics.<h4>Results</h4>Excursions with peak glucose ≥250 mg/dL and time to peak ≥90 min were significantly associated with higher uGMI-to-HbA1c ratios after adjustment for age, sex, estimated glomerular filtration rate, and HbA1c group, with consistent findings across CGM devices (sensor type 1: β = 0.174, 95% CI 0.147-0.201; sensor type 2: β = 0.102, 95% CI 0.068-0.136; both P < 0.001) and alternative GMI formulations.

Full abstract (original)

Background: <h4>Objective</h4>Discordance between the glucose management indicator (GMI) and hemoglobin A1c (HbA1c) is frequently observed in diabetes, yet its physiological basis remains unclear. This study investigated how specific glucose excursion patterns captured by continuous glucose monitoring (CGM) contribute to this discordance in individuals with type 1 diabetes.<h4>Research design and methods</h4>Ninety-day CGM traces from 611 adults with type 1 diabetes were paired with HbA1c results obtained within ±15 days.

What they did: Glucose excursions were quantified using the glucose rate increase detector (GRID) algorithm with varied peak glucose and time-to-peak thresholds. Discordance was defined using GMI-to-HbA1c and updated GMI (uGMI)-to-HbA1c ratios, and associations with GRID-derived excursion metrics were evaluated alongside conventional CGM-derived variability metrics.<h4>Results</h4>Excursions with peak glucose ≥250 mg/dL and time to peak ≥90 min were significantly associated with higher uGMI-to-HbA1c ratios after adjustment for age, sex, estimated glomerular filtration rate, and HbA1c group, with consistent findings across CGM devices (sensor type 1: β = 0.174, 95% CI 0.147-0.201; sensor type 2: β = 0.102, 95% CI 0.068-0.136; both P < 0.001) and alternative GMI formulations.

Results & conclusions: In restricted cubic spline analyses, adjustment for GRID-derived excursion metrics differentially reshaped the associations of HbA1c, GMI, and uGMI with albuminuria and elevated triglyceride-glucose index in an outcome- and context-dependent manner, preferentially enhancing the informativeness of GMI and uGMI but not HbA1c.<h4>Conclusions</h4>Frequent high and prolonged glucose excursions were consistently associated with GMI-HbA1c discordance across devices, HbA1c strata, and analytic conditions. GRID-derived excursion metrics modify the relationship between GMI/uGMI and glycemia-associated risk.

Abstract © the authors / Diabetes Care (2026). Reproduced here for discussion and indexing, with attribution. Read the original at https://doi.org/10.2337/dc25-2820 · PubMed 42081254.

Why it matters for pharma & biotech

  • Relevant to Pharmacology & Drug Discovery teams tracking Diabetes Care for new targets, mechanisms and biomarkers.
  • As earlier-stage work, its near-term value is target validation and assay design rather than clinical decisions.
  • For searchers: the full abstract is reproduced below, so you can judge relevance before opening the publisher page.

Limitations & what to check in the full text

  • This brief is based on the published abstract only. Effect sizes, subgroup results and safety detail in the full text may qualify the headline findings.

Frequently asked questions

What did this Diabetes Care study find?

GRID-derived excursion metrics modify the relationship between GMI/uGMI and glycemia-associated risk.

What type of study is this?

It is a research study, published in Diabetes Care in 2026. Glucose excursions were quantified using the glucose rate increase detector (GRID) algorithm with varied peak glucose and time-to-peak thresholds.

Where can I read the original paper?

The original is at the publisher via DOI 10.2337/dc25-2820. PubMed ID: 42081254. BioStudioAI reproduces the abstract for discussion and links to the source.

How to cite the original: Park S, Cho SH, Kim S et al.. High-Amplitude and Prolonged Glucose Excursions as a Key Determinant of Discordance Between Glucose Management Indicator and Glycated Hemoglobin in Type 1 Diabetes.. Diabetes Care (2026). DOI: 10.2337/dc25-2820.
This brief: BioStudioAI Journal Watch, 29 October 2026. https://biostudioai.com/blog/papers/high-amplitude-and-prolonged-glucose-excursions-as-a-key-determinant-of-252820/

Reading papers is step one. Analysing the data is the work.

BioStudioAI turns raw lab files into QC'd results, statistics, figures, reports and slides — hosted on your servers, every number computed, nothing typed.

Open BioStudioAI More guides