Assay validation basics: precision, accuracy, range

Last reviewed Author: BioStudioAI

Answer first. Validation shows an assay measures what it claims, in the matrix it claims, over the range it claims. Precision, accuracy, range, specificity and robustness are demonstrated with designed experiments, following ICH M10 and CLSI thinking where they apply.

Validation shows an assay measures what it claims, in the matrix it claims, over the range it claims. Precision, accuracy, range, specificity and robustness are demonstrated with designed experiments, following ICH M10 and CLSI thinking where they apply.

Worked example

Take a concrete case and work it with the matching calculator in Tools rather than by hand, so the arithmetic is checkable. Record the inputs, the formula and the result together; the calculator pages on this hub show each step with your numbers, which is the same discipline to apply in a notebook or report. When the example involves a curve, check back-calculated standards or residuals before quoting the sample result, and state the units at every step.

Common mistakes

MistakeWhy it changes the answer
Reading samples outside the validated rangeSmall signal errors become large concentration errors
Testing on technical replicates as if biologicalSample size and significance are overstated
Choosing the analysis after seeing the dataAny threshold can be made to look favourable
Reporting a summary without the individual pointsFailed replicates and bimodal data stay hidden

FAQ

QuestionAnswer
What should I report with the result?The method and version, controls, acceptance criteria, exclusions with reasons, and the raw file identifier.
Where do I calculate it?Use the matching free calculator in Tools; it shows its working.

Link up to the topic hub for this assay family, run the matching Protocol for the bench method, and see Troubleshooting when a run fails these criteria. Have plates of this data? BioStudioAI fits, quality-checks and reports them with an audit trail: see /platform/.

Frequently asked questions

What should I report?

Method, controls, acceptance criteria, exclusions and the raw file.

References

  1. Assay Guidance Manual · NCBI Bookshelf (2024)
  2. MIQE Guidelines · Clinical Chemistry (2009)
  3. ICH M10 Bioanalytical Method Validation · ICH (2022)

Do this analysis in BioStudioAI

Upload the raw file and BioStudioAI fits, quality-checks and reports it with an audit trail.

See the platform →

Related

Miniaturizing an assay from 96 to 384 wells

Volumes shrink 4-fold but evaporation, meniscus and pipetting errors do not. Re-validate Z-prime, edge behaviour and liquid handling at the new scale

The precision profile: CV across the range

Precision varies with concentration, worst near the limits. A precision profile (CV versus level) defines where the assay may honestly report numbers

Transferring an assay between labs or sites

Assay transfer is a designed comparison: shared samples and standards, pre-set equivalence criteria, and both sites' raw data retained. A protocol PDF

Plate assay QC